Safety Mat Junction Boxes with Easy Tie-In for Grouping up to 10 safety mats. Part No. RKR-021 Mat junction box can provide wiring for up to 10 mats for easy tie-in to the mat control. (Cover has been removed for photo.) If multiple mats are grouped together to provide auxiliary or perimeter (work-envelope) safeguarding, junction…
Lathe chuck wrenches help prevent one of the most common accidents on lathes: when a chuck wrench (or key) is thrown from the chuck. This happens when someone forgets to remove the chuck wrench from the chuck before the machine is turned on. A self-ejecting, spring-loaded chuck wrench can be used on lathes or other…
Power Interruption Immune, Sensing-Saf-Start® Package The Sensing-Saf-Start® package is designed for installation on 120-V (15-A maximum) machines. When installed correctly, the Saf-Start® package will prevent the machine from automatically or unintentionally restarting when a power interruption occurs. The machine cannot restart until power has been restored, the machine has been turned off, and the reset…
The 115VAC, 30A non-reversing magnetic motor starter, self-latching red emergency-stop palm button, green motor control on push button and red motor control off push button are housed in a NEMA 12 enclosure. Enclosure size is 8″ x 6″ x 6″. It can be used for machines with 115VAC power and is rated up to 2…
The 115VAC, 20A non-reversing magnetic motor starter, self-latching red emergency-stop palm button, green motor control on push button and red motor control off push button are housed in a NEMA 4 polycarbonate enclosure. Enclosure size is 5″ x 5″ x 4″. It can be used for machines with 115VAC power and is rated up to…
Tamper-resistant safety switches can be used to interlock hinged, sliding, or lift-off guards. Closure of the guard or latch causes the actuator to enter the switch and release the dual anti-tamper locking cams. The actuator allows the main center cam to rotate and make the switch contacts. When opening the guard or latch, the actuator…
Kit includes switch, actuator, and conduit adapter. Locking switches are designed to prevent accidental or deliberate access while the machine is in motion. The mechanical locking feature is ideal for machines that have to finish a sequence, a program, or coast to a stop before the interlocked guard can be opened. The switches allow the…
Spring-loaded turnover bars are most frequently used with mechanical power presses. Turnover bars can also be used on four-slides or any other machine where the bar might be sent into the air if it is inadvertently left in the bar ring hole and the machine is turned on. Each spring-loaded turnover bar is self-ejecting so…
Use the chart below to select your drill press chuck key. These drill press chuck keys are spring-loaded and self-eject so they are not inadvertently left in the drill’s chuck. Drill Press Chuck Keys – Pilot Size Selection Chart
Bench grinder shields are designed to minimize the debris and hazards associated with bench grinders and buffers. These standard-mount grinder shields are available in various sizes for protection from the swarf of bench or pedestal grinders. The frames are constructed of reinforced fiber nylon or heavy cast aluminum. Each shield is furnished with a threaded…
Two-Hand Control, Standard Palm Button Assemblies To meet OSHA and ANSI safety requirements, the two run/inch buttons must be protected against accidental operation (with ring guards) and they must be separated to require the use of both hands to operate them. They must also be mounted at the proper safety distance if they will be…
The heavy-duty, standard-voltage articulated palm button provides 1 NO and 1 NC contact arrangement. This 2 3/4″ chrome button comes with a guard, gasket, and four screws. This palm button can be used instead of the standard palm button when a lighter push or a more ergonomic button is required. The force required to operate…
This steel safety block base can be added to U-shaped, octagonal-shaped, and X-shaped safety blocks. The base adds stability to help prevent the die block from tipping over. Available in 1/2″-thick steel. To learn more about die blocks, we invite you to read our blog post “Demystifying Die Safety Blocks.” Aluminum safety block bases are…
Actuators must NEVER be used to bypass or otherwise defeat the protective functions of the safety switch.
The four-finger grip and larger cup provide extra lifting capacity. Its larger diameter makes this lifter ideal for greater loads. Breaks oil adhesions easily. It also has specially designed release tabs. Lifts about 12 pounds. 4 3/4″ diameter cup.
Tagout signs meet OSHA 29 CFR 1910.147 for lockout/tagout. The reverse side of each tagout is the same. Tagouts are 2 7/8″ x 5 1/2″ x .055″ thick polyethylene material. Available styles include: Do Not Start Do Not Operate Do Not Open Do Not Close Do Not Energize
The tower light assembly control box provides a convenient means of mounting and wiring the tower light. The LLD1631 standard box comes with enough terminals to accommodate five (5) lights or four (4) lights with an alarm in the tower light assembly. This control box is approximately 8 inches x 6 inches x 6 inches.
Lightweight or Heavyweight Tweezers for Various Machinery Applications Part No. CYF-600 Lightweight tweezers. Total Length: 6 1/2″ Weight: 1 1/10 oz. Part No. CYF-601 Heavier tweezers. Total Length: 9″ Weight: 1 3/5 oz.
Open Monday – Friday
8:00am – 5:00pm CST
To reduce risk and prevent workplace
injuries by becoming our customer’s trusted
advisor and source for machine safeguarding
training, assessment services, and provider
of turnkey engineered safeguarding solutions.
5795 Logistics Parkway
Rockford Illinois 61109
1-800-922-7533
Copyright 2024. All Rights Reserved By Rockford Systems LLC
Rockford Combustion Solutions provides fuel-train management and combustion-safety solutions for safety-conscious organizations that work with fuel-fired equipment in thermal processes.
Rockford Combustion
5795 Logistics Parkway
Rockford, Illinois USA 61109